The MXA143 differs from standard circuits in that when it detects light, the relay activates, and when it gets dark, the relay remains active for a set period. This circuit is suitable for applications where turning on a light also activates other devices, such as a fan in a bathroom. When the bathroom light is turned on, this circuit activates. When the light switch is turned off, the bathroom fan continues to run for the pre-set time to remove odors.
Technical Specifications:
- Power supply: 12VDC
- Maximum current consumption: approximately 60 mA
- Built-in timer for delay off: 1-90 minutes
- Can be configured as a delay off timer
- Compatible with loads not exceeding 12V 1A or 220VAC up to 200W
- PCB size: 2.1 x 3.5 inches